AMPOULE / VIAL WASHING MACHINE

Vials Washing Process Ampoules Cleaning Process
• Ultrasonic treatment (optional)
• Recycled water (internal and external)
• Compressed air (internal)
• Purified water (internal)
• Compressed air (internal)
• WF1 (internal)
• Compressed air (internal)
• Ultrasonic cleaning
• Internal and external cleaning by spraying with Re-circulated water (1-Station)
• Internal blow-dry with compressed air (1-Station)
• Spraying with Purified water
• Internal blow-dry with compressed air
• Spraying with WFI (1-Station)
• Internal and external blow dry with compressed air (2-Stations)

Technical Specifications

Output of the machine 300 Amp/min
16Head D 10-16mm
12 Head D 18-25 mm

Salient Features

  • All parts that come in contact with the internal surface of the ampoule/ vial and wash media are made of AISI SS 316L stainless steel.
  • Other parts are made from engineering plastics, FDA approved or AISI SS 304 stainless steel.
  •  The washing process can be customized to your requirement. Each vial or ampoule is guided through a series of process steps.
  • Short set up time, fast & simple size change ensures versatility of use for different ampoule/vial
  • All electronically controlled features of machine can be equipped through PLC with operational data logging system for the documentation of all data relevant to the production

Vaccines

Serums

Plasma Fractions

 Suspensions

Infusion Solutions

Your Process. Our Precision.

Partner with Intertech Technologies for scalable, GMP-compliant machinery trusted by the world’s leading manufacturers.